Meeting Room Capacity Calculator

Estimate how many small, medium and large meeting rooms your office needs, and how busy they will be at peak. Free, runs in your browser, nothing is stored.

Your office and meetings

%

Only count meetings held in a room, not calls taken at a desk.

min

h

Editable assumptions

These are starting points, not measured statistics. Replace them with your own data.

How much busier your busiest hour is than the average hour.

%

Lower means more spare rooms in the busiest hour.

Meeting size mix (relative shares, normalised automatically)

Your estimate

Recommended meeting rooms

16

Expected peak utilization 63% across all rooms

Rooms for 2–4 people

9

43 meetings/day, 68% peak utilization

Rooms for 5–8 people

5

22 meetings/day, 61% peak utilization

Rooms for 9+ people

2

7 meetings/day, 51% peak utilization

About 72 meetings and 54 room-hours of demand per day.

Start your free trialBook a demo

What the result means

Rooms are sized for your busiest hour, not the daily average, because that is when people fail to find one. Each size bucket is calculated separately so you do not end up with plenty of large rooms and no space for two-person conversations. Reservete shows live room availability and real usage, so you can adjust room counts and sizes against what people actually book.

Method and limitations

Meetings per day = (employees × share in office × meetings per person) ÷ average attendees. Room-hours = meetings × length ÷ 60.

For each size bucket: peak rooms in use = (room-hours ÷ working hours) × peak-hour factor. Rooms recommended = ceil(peak rooms in use ÷ target utilization), minimum 1 where there is demand. Expected peak utilization = peak rooms in use ÷ rooms recommended.

This is an estimate. It uses one average attendee count and an editable size mix, so a real meeting-size distribution may differ. It ignores changeover time, people booking larger rooms than needed, video-only meetings at desks, room features and seasonality. Compare it with your calendar or booking data before building or removing rooms. Nothing you enter leaves your browser.

Frequently asked questions

How does this calculator estimate meeting room demand?

It takes the people in the office, multiplies by meetings per person, and divides by the average attendees to get the number of distinct meetings. Multiplying by meeting length gives room-hours per day, which is spread over your working hours and scaled by a peak-hour factor.

What does the peak-hour factor mean?

Meetings are not spread evenly across the day; many cluster mid-morning and early afternoon. The peak-hour factor says how much busier your busiest hour is than the average hour. The default of 1.5 is an editable assumption, not a measured statistic. Use your own calendar or booking data if you have it.

Why is there a target utilization?

Running rooms at 100% in the busiest hour means people regularly cannot find one. The target utilization is the peak load you are comfortable with. A lower target gives more rooms and more spare capacity; a higher target gives fewer rooms and more risk of contention.

Why split rooms into size buckets?

A small huddle room cannot host a nine-person meeting, and a large room is wasteful for a two-person call. The size mix is an editable assumption you should set from how your teams really meet. The calculator sizes each bucket separately.

What does this calculator not account for?

It ignores people using a larger room for a small meeting, back-to-back changeover time, video-call-only meetings held at desks, room features such as equipment, and seasonal variation. Treat the output as a planning starting point and validate it against real booking data.